Data
& Results
Table
1: Adhesive Sample Testing Data; Seawater samples were immersed
for approximately 80 days before testing.
Sample
Code |
Test
Type |
Dimensions
(in
x in) |
Area
(in2) |
Coverage
(estimated) |
Max.
Force
(Lb) |
AquaMend
- AC |
Tension
Lap Shear |
1.574
x 1.4875 |
2.341 |
100% |
642 |
FastCure
4200 - AC |
Tension
Lap Shear |
1.550
x 1.525 |
2.356 |
80% |
321 |
FastCure
5200 - AC |
Tension
Lap Shear |
1.524
x 1.4625 |
3.385 |
100% |
110 |
PSI
326 - AC |
Tension
Lap Shear |
1.527
x 1.528 |
2.333 |
100% |
241 |
3M
5200 - AC |
Tension
Lap Shear |
1.492
x 1.487 |
2.218 |
100% |
101 |
AquaMend
- SW |
Tension
Lap Shear |
1.486
x 1.590 |
2.363 |
100% |
502 |
FastCure
4200 - SW |
Tension
Lap Shear |
1.569
x 1.528 |
2.398 |
100% |
420 |
FastCure
5200 - SW |
Tension
Lap Shear |
1.549
x 1.488 |
2.304 |
100% |
121.5 |
PSI
326 - SW |
Tension
Lap Shear |
1.511
x 1.558 |
2.353 |
75% |
65.5 |
3M
5200 - SW |
Tension
Lap Shear |
1.522
x 1.676 |
2.550 |
100% |
91 |
AC – Air
Cured
SW – Sea
Water Cured
Table
2: Adhesive Sample Strengths
Sample
Code |
Test
Type |
Bond Strength
Measured Area (psi) |
Bond Strength
Estimated Area (psi) |
Bond Strength
Specified Value (psi) |
Deviation
from
Specified
Value (%) |
AquaMend
- AC |
Tension
Lap Shear |
274.2 |
274.2 |
* |
* |
FastCure
4200 - AC |
Tension
Lap Shear |
136.2 |
170.3 |
* |
* |
FastCure
5200 - AC |
Tension
Lap Shear |
32,5 |
32,5 |
* |
* |
PSI
326 - AC |
Tension
Lap Shear |
103.3 |
103.3 |
* |
* |
3M
5200 - AC |
Tension
Lap Shear |
45.5 |
45.5 |
* |
* |
AquaMend
- SW |
Tension
Lap Shear |
212.4 |
212.4 |
* |
* |
FastCure
4200 - SW |
Tension
Lap Shear |
175.1 |
175.1 |
* |
* |
FastCure
5200 - SW |
Tension
Lap Shear |
52.7 |
35.7 |
* |
* |
PSI
326 - SW |
Tension
Lap Shear |
27.8 |
37.1 |
* |
* |
3M
5200 - SW |
Tension
Lap Shear |
35.7 |
35.7 |
* |
* |
AC – Air
Cured
SW – Sea
Water Cured were immersed for about 80 days
* Reference